combined/waste water pipe

CANALTUB

PE-HD pipes and fittings with profiled outer wall to DIN EN 13476-3 as gravity line, for the discharge of combined waste water sewer pipe

Application

Pipelines for the discharge of polluted waste water and storm water in need of treatment from residential and commercial buildings are carried out with so-called combined waste water or waste water sewer pipes. Today, in most cases, a separate system is used for the discharge of waste water and surface water. However, there are still combined waste water pipelines, if required by the local conditions. The CANALTUB waste water sewer system from PE-HD to DIN EN 13476-3 is superior by its long service life and its stability towards the usual pollutants in sewage water.

  • Polyethylene twin wall pipe to DIN EN 13476-3
  • Size range from DN 150 to DN 500 (I. D. series)
  • Outside corrugated/inside smooth
  • Ring stiffness S ≥ 10.0 kN/m² to DIN EN ISO 9969 (SN 10)
  • PE grades used: PE 80/PE 100
  • Quality-assured by SKZ with test and inspection mark

  • Suitable for SLW 60 classified roads
  • Resistant to abrasion and biochemical attacks
  • Resistant to high-pressure flushing to DIN 19523
  • Temperature-resistant from -20 °C to +80 °C
  • Leak-tight to DIN EN ISO 13259
  • Guaranteed service life of PE-HD ≥ 100 years to      DIN 8074

  • Easy handling
  • Low weight
  • High impact resistance – rupture-proof, even at low temperatures
  • Proven inspection possibility
  • Rapid construction progress, economic basis for calculation
  • Extensive range of accessories

The connecting element, HP-CONNECT, is used in the initial installation or for a subsequent connection to the storm and waste water sewer system.

  • Pipes to be connected: DN 150/DN 200
  • Nominal size collectors: DN 250 to DN 800
  • With self-optimising sealing function
  • Hydraulically optimised internal geometry
  • No components protruding into the pipe
  • Resistant to shearing forces

HP-CONNECT connecting element

Size range

Nominal size DN 150 200 250 300 400 500
Outside diameter (mm) 174.8 234.8 293.4 352.7 463.8 579.4
Inside diameter (mm) 152.0 202.5 254.8 301.0 394.0 497.0